      National acceptance criteria of security doors
      View:4640 Release Date :2015/5/29 11:37:29

      Security doors acceptance criteria

       

      Installation, commissioning and acceptance criteria:

       

      Cargo installation, acceptance will strictly in accordance with national standards, standard, strict implementation of GB 15210-2003 standard formula through the security gate was.

      1. Preliminary Acceptance

      Consumer goods reach the designated place, the staff will be invited to check with consumer goods packaging is intact, check the number and send the goods to the parts list are the same.

      2. Unpacking

      Accompanied by consumer staff unpack the goods, according to the list on the packing list, inventory items arrive.

      3. Installation

      This step is done by our staff, our staff will be the equipment installation and commissioning.

      4. Acceptance Criteria

      Acceptance criteria for GB, (with the actual situation according to industry standards) subject matter, as follows:

      . a mechanical structure of acceptance:

      1) The skin should be intact, flat and smooth surface, uniform color, no obvious mechanical damage, the coating should not have blistering damage, no corrosion of metal parts, plastic parts no blistering, cracking.

      2) All equipment parts, components have sufficient rigidity, all regulation, control mechanism installed properly, flexible operation. Panel legible.

      3) easy to disassemble and assemble.

      4) The whole frame stiffness and strength should meet normal move will not be damaged.

       

      . b Electrical Technology:

      1) Power supply voltage in the range of 220V ± 15% of normal work.

      2) Insulation resistance: When using the AC power so accessible metal parts in the insulation resistance between the terminals of the power supply under normal conditions of not less than 100 MΩ, in wet conditions shall be less than 2 MΩ.

      3) Leakage current: ACCESSIBLE parts and ground and between the two parts may touch leakage current should not exceed 0.5mA rms sinusoidal, non-sinusoidal should not exceed 0.7mA peak or 2mA DC value.

       

      C. metal detector test should have the following phenomena:

      1) exceeds the limit of the metal alarm when an alarm signal is carried by type with the specified display and / or sound.

      2) When should call the police carried through the metal objects, but no alarm detector gate

      3) has not been detected or should not alarm the metal objects pass through the security gate was wrong alarms.

      4) The standard test them stands 1.55m-1.85m, weight 50.kg-90kg, do not carry any metal or conductive material, the body nor any future embedded by people. (Security doors in public places are generally not up to standard test people ask, such as "human body can not take any metal," according to industry standard test case, to exclude a large belt detect contraband control of the tool.)